In this paper, the most recent advances in the time-domain reflectometry (TDR)-based system for leak localization in underground pipes are described in detail. More specifically, a new design of sensing element and the use of a new connection modality are proposed. Thanks to these new features, the practical implementation of the system becomes much quicker and its use more effective. Additionally, the present work also describes all the practical aspects and technical details (from installation to functional tests), related to the practical implementation of the system. Finally, to assess the possibility of further increasing the cost-effectiveness of the TDR-based leak localization system, experimental tests were carried out by comparatively using two TDR instruments, differing in specifications and costs, to identify the position of a leak.

Recent advances in the TDR-based leak detection system for pipeline inspection / Cataldo, Andrea; De Benedetto, Egidio; Cannazza, Giuseppe; Masciullo, Antonio; Giaquinto, Nicola; D’Aucelli, Giuseppe Maria; Costantino, Nicola; De Leo, Antonio; Miraglia, Marcello. - In: MEASUREMENT. - ISSN 0263-2241. - STAMPA. - 98:(2016), pp. 347-354. [10.1016/j.measurement.2016.09.017]

Recent advances in the TDR-based leak detection system for pipeline inspection

Giaquinto, Nicola;D’Aucelli, Giuseppe Maria;Costantino, Nicola;
2016-01-01

Abstract

In this paper, the most recent advances in the time-domain reflectometry (TDR)-based system for leak localization in underground pipes are described in detail. More specifically, a new design of sensing element and the use of a new connection modality are proposed. Thanks to these new features, the practical implementation of the system becomes much quicker and its use more effective. Additionally, the present work also describes all the practical aspects and technical details (from installation to functional tests), related to the practical implementation of the system. Finally, to assess the possibility of further increasing the cost-effectiveness of the TDR-based leak localization system, experimental tests were carried out by comparatively using two TDR instruments, differing in specifications and costs, to identify the position of a leak.
2016
Recent advances in the TDR-based leak detection system for pipeline inspection / Cataldo, Andrea; De Benedetto, Egidio; Cannazza, Giuseppe; Masciullo, Antonio; Giaquinto, Nicola; D’Aucelli, Giuseppe Maria; Costantino, Nicola; De Leo, Antonio; Miraglia, Marcello. - In: MEASUREMENT. - ISSN 0263-2241. - STAMPA. - 98:(2016), pp. 347-354. [10.1016/j.measurement.2016.09.017]
File in questo prodotto:
File Dimensione Formato  
Postprint_Recent_advances_in_the_TDR_based_leak_detection_system_for_pipeline_inspection.pdf

accesso aperto

Descrizione: Accepted manuscript
Tipologia: Documento in Post-print
Licenza: Creative commons
Dimensione 3.21 MB
Formato Adobe PDF
3.21 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/83580
Citazioni
  • Scopus 43
  • ???jsp.display-item.citation.isi??? 32
social impact