A detailed review on the design and realization of spectrophones exploiting custom quartz tuning forks (QTFs) aimed to applications of quartz-enhanced photoacoustic (QEPAS) trace-gas sensors is reported. A spectrophone consists of a custom QTF and a micro-resonator system based on a pair of tubes (dual-tube configuration) or a single-tube. The influence of the QTF and resonator tube geometry and sizes on the main spectrophone parameters determining the QEPAS performance, specifically the quality factor Q and the resonance frequency has been investigated. Results obtained previously are reviewed both when the QTF vibrates on the fundamental and the first overtone flexural modes. We also report new results obtained with a novel QTF design. Finally, we compare the QEPAS performance of all the different spectrophone configurations reported in terms of signal-to-noise ratio and provide relevant and useful conclusions from this analysis.
Quartz–enhanced photoacoustic spectrophones exploiting custom tuning forks: a review / Patimisco, Pietro; Sampaolo, Angelo; Zheng, Huadan; Dong, Lei; Tittel, Frank K.; Spagnolo, Vincenzo. - In: ADVANCES IN PHYSICS: X. - ISSN 2374-6149. - ELETTRONICO. - 2:1(2017), pp. 169-187. [10.1080/23746149.2016.1271285]
Quartz–enhanced photoacoustic spectrophones exploiting custom tuning forks: a review
Patimisco, Pietro;Sampaolo, Angelo;Spagnolo, Vincenzo
2017-01-01
Abstract
A detailed review on the design and realization of spectrophones exploiting custom quartz tuning forks (QTFs) aimed to applications of quartz-enhanced photoacoustic (QEPAS) trace-gas sensors is reported. A spectrophone consists of a custom QTF and a micro-resonator system based on a pair of tubes (dual-tube configuration) or a single-tube. The influence of the QTF and resonator tube geometry and sizes on the main spectrophone parameters determining the QEPAS performance, specifically the quality factor Q and the resonance frequency has been investigated. Results obtained previously are reviewed both when the QTF vibrates on the fundamental and the first overtone flexural modes. We also report new results obtained with a novel QTF design. Finally, we compare the QEPAS performance of all the different spectrophone configurations reported in terms of signal-to-noise ratio and provide relevant and useful conclusions from this analysis.File | Dimensione | Formato | |
---|---|---|---|
AdV Phys X rev_2016.pdf
accesso aperto
Descrizione: Articolo principale
Tipologia:
Versione editoriale
Licenza:
Creative commons
Dimensione
2.17 MB
Formato
Adobe PDF
|
2.17 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.