In this paper detailed curves showing the behaviour of resistive plate chambers efficiency and time resolution as a function of temperature and operating voltage are presented. The results show that the operating voltage scales well according to the rule: operating voltage/gas density = constant.
Resistive Plate Chambers Performances at Cosmic-Rays Fluxes / Abbrescia, M; Cardarelli, R; Iaselli, G; Natali, S; Nuzzo, S; Ranieri, A; Romano, F; Santonico, R. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 359:3(1995), pp. 603-609. [10.1016/0168-9002(94)01698-4]
Resistive Plate Chambers Performances at Cosmic-Rays Fluxes
Iaselli, G;
1995-01-01
Abstract
In this paper detailed curves showing the behaviour of resistive plate chambers efficiency and time resolution as a function of temperature and operating voltage are presented. The results show that the operating voltage scales well according to the rule: operating voltage/gas density = constant.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.