The aim of this paper is to analyze the stability problems of grid connected inverters used in distributed generation. Complex controllers (e.g., multiple rotating dq-frames or resonant-based) are often required to compensate low frequency grid voltage background distortion and an LCL-filter is usually adopted for the high frequency one. The possible wide range of grid impedance values (distributed generation is suited for remote areas with radial distribution plants) challenge the stability and the effectiveness of the LCL-filter-based current controlled system. It has been found out and it will be demonstrated in this paper that the use of active damping helps to stabilise the system in respect to many different kinds of resonances. The use of active damping results in an easy plug-in feature of the generation system in a vast range of grid conditions and in a more flexible operation of the overall system able to manage sudden grid changes. In the paper, a vast measurement campaign made on a single-phase system and on a three-phase system used as scale prototypes for photovoltaic and wind turbines, respectively, validate the analysis.

Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values / Liserre, Marco; Teodorescu, R; Blaabjerg, F.. - In: IEEE TRANSACTIONS ON POWER ELECTRONICS. - ISSN 0885-8993. - 21:1(2006), pp. 263-272. [10.1109/TPEL.2005.861185]

Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values

LISERRE, Marco;
2006-01-01

Abstract

The aim of this paper is to analyze the stability problems of grid connected inverters used in distributed generation. Complex controllers (e.g., multiple rotating dq-frames or resonant-based) are often required to compensate low frequency grid voltage background distortion and an LCL-filter is usually adopted for the high frequency one. The possible wide range of grid impedance values (distributed generation is suited for remote areas with radial distribution plants) challenge the stability and the effectiveness of the LCL-filter-based current controlled system. It has been found out and it will be demonstrated in this paper that the use of active damping helps to stabilise the system in respect to many different kinds of resonances. The use of active damping results in an easy plug-in feature of the generation system in a vast range of grid conditions and in a more flexible operation of the overall system able to manage sudden grid changes. In the paper, a vast measurement campaign made on a single-phase system and on a three-phase system used as scale prototypes for photovoltaic and wind turbines, respectively, validate the analysis.
2006
Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values / Liserre, Marco; Teodorescu, R; Blaabjerg, F.. - In: IEEE TRANSACTIONS ON POWER ELECTRONICS. - ISSN 0885-8993. - 21:1(2006), pp. 263-272. [10.1109/TPEL.2005.861185]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/9726
Citazioni
  • Scopus 1040
  • ???jsp.display-item.citation.isi??? 781
social impact