Numerical simulations of counterflow laminar diffusion flames impinged by sub-breakdown DC electric fields are performed in this work using multi-component transport and a detailed chemical mechanism for methane–air combustion that includes elementary steps for the conversion of six electrically charged species. The electric field is induced by two electrodes located on the oxidizer and fuel sides and arranged parallel to the mixing layer in a configuration resembling the one recently studied experimentally by Park et al. (2016) [1], which unveiled significant electric-field effects on the aerodynamics. In these simulations, the electric drift of the charged species leads to a bi-directional ionic wind that is axially directed toward both injectors. The major components of the ionic winds are the H3O+and O2−ions, which are steered by the electric field into the fuel and oxidizer streams, respectively. At sufficiently high electric fields of the order of a few kilovolts per centimeter, the ionic wind intricately couples with the aerodynamic field of neutral molecules flowing into the burner, in a manner that ultimately leads to non-negligible disturbances of the velocity field. The overall effect of these interactions consists of a decrease in the local strain rate and in the stoichiometric scalar dissipation rate, which increases the burning rate of the diffusion flame. The functional form of the scalar dissipation rate depends on the applied electric field, which may have consequences for the subgrid-scale modeling of these processes. In contrast to electrified one-dimensional premixed flames, here the current ceases to vary monotonically with the voltage as a result of the coupling with the aerodynamic field. Comparisons between the present numerical simulations and the experiments performed by Park et al. (2016) [1] are made that indicate qualitative agreement. Quantitative disagreements related to the saturation intensities and to the strength of the electric disturbances of the velocity field are discussed, and possible sources of these discrepancies are identified.

The effects of incident electric fields on counterflow diffusion flames / Di Renzo, M.; Urzay, J.; De Palma, P.; de Tullio, M. D.; Pascazio, G.. - In: COMBUSTION AND FLAME. - ISSN 0010-2180. - STAMPA. - 193:(2018), pp. 177-191. [10.1016/j.combustflame.2018.03.001]

The effects of incident electric fields on counterflow diffusion flames

Di Renzo, M.;De Palma, P.;de Tullio, M. D.;Pascazio, G.
2018-01-01

Abstract

Numerical simulations of counterflow laminar diffusion flames impinged by sub-breakdown DC electric fields are performed in this work using multi-component transport and a detailed chemical mechanism for methane–air combustion that includes elementary steps for the conversion of six electrically charged species. The electric field is induced by two electrodes located on the oxidizer and fuel sides and arranged parallel to the mixing layer in a configuration resembling the one recently studied experimentally by Park et al. (2016) [1], which unveiled significant electric-field effects on the aerodynamics. In these simulations, the electric drift of the charged species leads to a bi-directional ionic wind that is axially directed toward both injectors. The major components of the ionic winds are the H3O+and O2−ions, which are steered by the electric field into the fuel and oxidizer streams, respectively. At sufficiently high electric fields of the order of a few kilovolts per centimeter, the ionic wind intricately couples with the aerodynamic field of neutral molecules flowing into the burner, in a manner that ultimately leads to non-negligible disturbances of the velocity field. The overall effect of these interactions consists of a decrease in the local strain rate and in the stoichiometric scalar dissipation rate, which increases the burning rate of the diffusion flame. The functional form of the scalar dissipation rate depends on the applied electric field, which may have consequences for the subgrid-scale modeling of these processes. In contrast to electrified one-dimensional premixed flames, here the current ceases to vary monotonically with the voltage as a result of the coupling with the aerodynamic field. Comparisons between the present numerical simulations and the experiments performed by Park et al. (2016) [1] are made that indicate qualitative agreement. Quantitative disagreements related to the saturation intensities and to the strength of the electric disturbances of the velocity field are discussed, and possible sources of these discrepancies are identified.
2018
The effects of incident electric fields on counterflow diffusion flames / Di Renzo, M.; Urzay, J.; De Palma, P.; de Tullio, M. D.; Pascazio, G.. - In: COMBUSTION AND FLAME. - ISSN 0010-2180. - STAMPA. - 193:(2018), pp. 177-191. [10.1016/j.combustflame.2018.03.001]
File in questo prodotto:
File Dimensione Formato  
18_detullio_Comb post-print open.pdf

accesso aperto

Descrizione: Accepted manuscript
Tipologia: Documento in Post-print
Licenza: Creative commons
Dimensione 2.84 MB
Formato Adobe PDF
2.84 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/128798
Citazioni
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 19
social impact