In recent years, pumps operated as turbines (PaTs) have been gaining the interest of industry and academia. For instance, PaTs can be effectively used in micro hydropower plants (MHP) and water distribution systems (WDS). Therefore, further efforts are necessary to investigate their fluid dynamic behavior. Compared to conventional turbines, a lower number of blades is employed in PaTs, lowering their capability to correctly guide the flow, hence reducing the Euler’s work; thus, the slip phenomenon cannot be neglected at the outlet section of the runner. In the first part of the paper, the slip phenomenon is numerically investigated on a simplified geometry, evidencing the dependency of the lack in guiding the flow on the number of blades. Then, a commercial double suction centrifugal pump, characterized by the same specific speed, is considered, evaluating the dependency of the slip on the flow rate. In the last part, a slip factor correlation is introduced based on those CFD simulations. It is shown how the inclusion of this parameter in a 1-D performance prediction model allows us to reduce the performance prediction errors with respect to experiments on a pump with a similar specific speed by 5.5% at design point, compared to no slip model, and by 8% at part-loads, rather than using Busemann and Stodola formulas.

Slip Factor Correction in 1-D Performance Prediction Model for PaTs / Capurso, Tommaso; Stefanizzi, Michele; Pascazio, Giuseppe; Ranaldo, Sergio; Camporeale, Sergio Mario; Fortunato, Bernardo; Torresi, Marco. - In: WATER. - ISSN 2073-4441. - ELETTRONICO. - 11:3(2019). [10.3390/w11030565]

Slip Factor Correction in 1-D Performance Prediction Model for PaTs

Tommaso Capurso
;
Michele Stefanizzi;Giuseppe Pascazio;Sergio Ranaldo;Sergio Mario Camporeale;Bernardo Fortunato;Marco Torresi
2019-01-01

Abstract

In recent years, pumps operated as turbines (PaTs) have been gaining the interest of industry and academia. For instance, PaTs can be effectively used in micro hydropower plants (MHP) and water distribution systems (WDS). Therefore, further efforts are necessary to investigate their fluid dynamic behavior. Compared to conventional turbines, a lower number of blades is employed in PaTs, lowering their capability to correctly guide the flow, hence reducing the Euler’s work; thus, the slip phenomenon cannot be neglected at the outlet section of the runner. In the first part of the paper, the slip phenomenon is numerically investigated on a simplified geometry, evidencing the dependency of the lack in guiding the flow on the number of blades. Then, a commercial double suction centrifugal pump, characterized by the same specific speed, is considered, evaluating the dependency of the slip on the flow rate. In the last part, a slip factor correlation is introduced based on those CFD simulations. It is shown how the inclusion of this parameter in a 1-D performance prediction model allows us to reduce the performance prediction errors with respect to experiments on a pump with a similar specific speed by 5.5% at design point, compared to no slip model, and by 8% at part-loads, rather than using Busemann and Stodola formulas.
2019
Slip Factor Correction in 1-D Performance Prediction Model for PaTs / Capurso, Tommaso; Stefanizzi, Michele; Pascazio, Giuseppe; Ranaldo, Sergio; Camporeale, Sergio Mario; Fortunato, Bernardo; Torresi, Marco. - In: WATER. - ISSN 2073-4441. - ELETTRONICO. - 11:3(2019). [10.3390/w11030565]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/167562
Citazioni
  • Scopus 27
  • ???jsp.display-item.citation.isi??? 20
social impact