The present paper describes a procedure improving the measurement of fluid flow rates in pipes through the measurement of vibrations. The authors show, via experimental tests for water system, that for a given pipe in terms of width, diameter and material, the first harmonic amplitude of the vibration signal transmitted from the flow to the pipe walls is linearly proportional to the flow rate at a given revolution of the pump. Then, accelerometer mini/micro-transducers can be used for non intrusive, low-cost and reliable flow rate measurements without load errors.
Fluid flow rate estimation using acceleration sensors / Dinardo, Giuseppe; Fabbiano, Laura; Vacca, Gaetano. - ELETTRONICO. - (2013), pp. 221-225. (Intervento presentato al convegno 7th International Conference on Sensing Technology, ICST 2013 tenutosi a Wellington; New Zealand nel December 3-5, 2013) [10.1109/ICSensT.2013.6727646].
Fluid flow rate estimation using acceleration sensors
Laura Fabbiano;Gaetano Vacca
2013-01-01
Abstract
The present paper describes a procedure improving the measurement of fluid flow rates in pipes through the measurement of vibrations. The authors show, via experimental tests for water system, that for a given pipe in terms of width, diameter and material, the first harmonic amplitude of the vibration signal transmitted from the flow to the pipe walls is linearly proportional to the flow rate at a given revolution of the pump. Then, accelerometer mini/micro-transducers can be used for non intrusive, low-cost and reliable flow rate measurements without load errors.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.