The TOTEM collaboration has developed and tested the first prototype of its Roman Pots to be operated in the LHC. TOTEM Roman Pots contain stacks of silicon detectors with strips oriented in two orthogonal directions. To measure proton scattering angles of a few microradians, the detectors will approach the beam centre to a distance of 10σ + 0.5 mm (= 1.3 mm). Dead space near the detector edge is minimised by using two novel "edgeless" detector technologies. The silicon detectors are used both for precise track reconstruction and for triggering. The first full-sized prototypes of both detector technologies as well as their read-out electronics have been developed, built and operated. The tests took place in the proton beam-line of the SPS accelerator ring. In addition, the pot's shielding against electromagnetic interference and the longitudinal beam coupling impedance have been measured with the wire method.
Tests of a Roman Pot Prototype for the Totem Experiment / M., Deile; E., Alagoz; G., Anelli; G., Antchev; M., Ayache; F., Caspers; E., Dimovasili; R., Dinapoli; F., Drouhin; K., Eggert; J. L., Escourrou; O., Fochler; K., Gill; R., Grabit; F., Haug; P., Jarron; J., Kaplon; T., Kroyer; T., Luntama; D., Macina; E., Mattelon; H., Niewiadomski; L., Mirabito; E. P., Noschis; M., Oriunno; A., Park; A. -L., Perrot; O., Pirotte; J. M., Quetsch; F., Regnier; G., Ruggiero; S., Saramad; P., Siegrist; W., Snoeys; T., Souissi; R., Szczygiel; J., Troska; F., Vasey; A., Verdier; C., DA VIA'; J., Hasi; A., Kok; S., Watts; J., Ka; Spar, ; V., Kundrat; M. V., Lokaji; Cek, ; J., Smotlacha; V., Avati; M., Jarvinen; M., Kalliokoski; J., Kalliopuska; K., Kurvinen; R., Lauhakangas; F., Oljemark; R., Orava; Sterberg, K. O.; V., Palmieri; H., Saarikko; A., Soininen; V., Boccone; M., Bozzo; A., Buzzo; S., Cuneo; F., Ferro; M., Macri; S., Minutoli; A., Morelli; P., Musico; M., Negri; A., Santroni; G., Sette; A., Sobol; Berardi, V; M. G., Catanesi; E., Radicioni. - STAMPA. - (2005), pp. 1590883.1701-1590883.1703. (Intervento presentato al convegno Particle Accelerator Conference, PAC 2005 tenutosi a Knoxville, TN nel May 16-20, 2005) [10.1109/PAC.2005.1590883].
Tests of a Roman Pot Prototype for the Totem Experiment
The TOTEM collaboration has developed and tested the first prototype of its Roman Pots to be operated in the LHC. TOTEM Roman Pots contain stacks of silicon detectors with strips oriented in two orthogonal directions. To measure proton scattering angles of a few microradians, the detectors will approach the beam centre to a distance of 10σ + 0.5 mm (= 1.3 mm). Dead space near the detector edge is minimised by using two novel "edgeless" detector technologies. The silicon detectors are used both for precise track reconstruction and for triggering. The first full-sized prototypes of both detector technologies as well as their read-out electronics have been developed, built and operated. The tests took place in the proton beam-line of the SPS accelerator ring. In addition, the pot's shielding against electromagnetic interference and the longitudinal beam coupling impedance have been measured with the wire method.
Tests of a Roman Pot Prototype for the Totem Experiment / M., Deile; E., Alagoz; G., Anelli; G., Antchev; M., Ayache; F., Caspers; E., Dimovasili; R., Dinapoli; F., Drouhin; K., Eggert; J. L., Escourrou; O., Fochler; K., Gill; R., Grabit; F., Haug; P., Jarron; J., Kaplon; T., Kroyer; T., Luntama; D., Macina; E., Mattelon; H., Niewiadomski; L., Mirabito; E. P., Noschis; M., Oriunno; A., Park; A. -L., Perrot; O., Pirotte; J. M., Quetsch; F., Regnier; G., Ruggiero; S., Saramad; P., Siegrist; W., Snoeys; T., Souissi; R., Szczygiel; J., Troska; F., Vasey; A., Verdier; C., DA VIA'; J., Hasi; A., Kok; S., Watts; J., Ka; Spar, ; V., Kundrat; M. V., Lokaji; Cek, ; J., Smotlacha; V., Avati; M., Jarvinen; M., Kalliokoski; J., Kalliopuska; K., Kurvinen; R., Lauhakangas; F., Oljemark; R., Orava; Sterberg, K. O.; V., Palmieri; H., Saarikko; A., Soininen; V., Boccone; M., Bozzo; A., Buzzo; S., Cuneo; F., Ferro; M., Macri; S., Minutoli; A., Morelli; P., Musico; M., Negri; A., Santroni; G., Sette; A., Sobol; Berardi, V; M. G., Catanesi; E., Radicioni. - STAMPA. - (2005), pp. 1590883.1701-1590883.1703. (Intervento presentato al convegno Particle Accelerator Conference, PAC 2005 tenutosi a Knoxville, TN nel May 16-20, 2005) [10.1109/PAC.2005.1590883].
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/23285
Citazioni
3
0
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.