This paper investigates the influence of a constant carrier phase shift on the DC-link capacitor harmonic current of cascaded converters used in fuel-cell and mild-hybrid electric vehicles. In these applications, a DC-DC converter can be adopted between the battery and the motor drive inverter in a cascaded structure, where the two converters share the same DC-link. Since the DC-link capacitor of such a system represents a critical component, the optimization of the converter operation to limit the current stress and extend the lifetime of the capacitor is an primary objective. This paper proposes the use of a carrier phase shift between the modulations of the two converters in order to minimize the harmonic current of the DC-link capacitor. By harmonic analysis, an optimal carrier phase shift can be derived depending on the converter configuration. Analytical results are presented and validated by hardware-in-the-loop experiments. The findings show that the pulse width modulation carrier phase shift between the interleaved boost converter and the voltage source motor drive inverter has a significant influence on the DC-link capacitor current and thus on its lifetime. A case study with two-cell and three-cell interleaved boost converters shows a possible DC-link capacitor lifetime extension of up to 390%.

Common DC-Link Capacitor Harmonic Current Minimization for Cascaded Converters by Optimized Phase-Shift Modulation / Zhou, X.; Choy, W. J.; Alcaide, A. M.; Wang, S.; Guenter, S.; Leon, J. I.; Monopoli, V. G.; Franquelo, L. G.; Liserre, M.; Galea, M.; Gerada, C.; Buticchi, G.. - In: ENERGIES. - ISSN 1996-1073. - 16:5(2023), p. 2098.2098. [10.3390/en16052098]

Common DC-Link Capacitor Harmonic Current Minimization for Cascaded Converters by Optimized Phase-Shift Modulation

Monopoli V. G.;
2023-01-01

Abstract

This paper investigates the influence of a constant carrier phase shift on the DC-link capacitor harmonic current of cascaded converters used in fuel-cell and mild-hybrid electric vehicles. In these applications, a DC-DC converter can be adopted between the battery and the motor drive inverter in a cascaded structure, where the two converters share the same DC-link. Since the DC-link capacitor of such a system represents a critical component, the optimization of the converter operation to limit the current stress and extend the lifetime of the capacitor is an primary objective. This paper proposes the use of a carrier phase shift between the modulations of the two converters in order to minimize the harmonic current of the DC-link capacitor. By harmonic analysis, an optimal carrier phase shift can be derived depending on the converter configuration. Analytical results are presented and validated by hardware-in-the-loop experiments. The findings show that the pulse width modulation carrier phase shift between the interleaved boost converter and the voltage source motor drive inverter has a significant influence on the DC-link capacitor current and thus on its lifetime. A case study with two-cell and three-cell interleaved boost converters shows a possible DC-link capacitor lifetime extension of up to 390%.
2023
Common DC-Link Capacitor Harmonic Current Minimization for Cascaded Converters by Optimized Phase-Shift Modulation / Zhou, X.; Choy, W. J.; Alcaide, A. M.; Wang, S.; Guenter, S.; Leon, J. I.; Monopoli, V. G.; Franquelo, L. G.; Liserre, M.; Galea, M.; Gerada, C.; Buticchi, G.. - In: ENERGIES. - ISSN 1996-1073. - 16:5(2023), p. 2098.2098. [10.3390/en16052098]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/249160
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact