The experimental analysis of the main figures of merit of an innovative electrochromic (EC) prototype, based on low cost gel-polymer electrolytes, is at the basis of the numerical simulation exposed hereafter, aiming at the assessment of energy and visual comfort benefits deriving from building integration of smart windows in a multi-storey office building. The effectiveness of the dynamic modulation of glazing properties to improve energy efficiency and users’ comfort was tested comparing the EC windows with a typical law-compliant static commercial glazing system and with a clear windows. To better understand the performances of the proposed EC film, six different locations – ranging from Seville to Helsinki – were selected throughout the European continent to conduct energy and daylighting analyses on three different exposures (east, south, west). The results obtained show reductions of summer cooling and winter heating as well in all the locations considered. Eventually, the effect of electrochromic switching of transmittance on the indoor visual comfort, is considered using a well-established metric: Useful Daylight Illuminance; with regards to daylight analyses, a significant reduction of hours in which excessive illuminance occurs was observed in all the locations considered, confirming that properly controlled EC devices improve both energy efficiency and visual comfort.

Low-cost gel-polymer electrolytes for smart windows: effects on yearly energy consumption and visual comfort / Cannavale, Alessandro; Carlucci, Francesco; Pugliese, Marco; Maiorano, Vincenzo; Ayr, Ubaldo; Fiorito, Francesco. - In: ENERGY AND BUILDINGS. - ISSN 0378-7788. - STAMPA. - 301:(2023). [10.1016/j.enbuild.2023.113705]

Low-cost gel-polymer electrolytes for smart windows: effects on yearly energy consumption and visual comfort

Alessandro Cannavale;Francesco Carlucci;Ubaldo Ayr;Francesco Fiorito
2023-01-01

Abstract

The experimental analysis of the main figures of merit of an innovative electrochromic (EC) prototype, based on low cost gel-polymer electrolytes, is at the basis of the numerical simulation exposed hereafter, aiming at the assessment of energy and visual comfort benefits deriving from building integration of smart windows in a multi-storey office building. The effectiveness of the dynamic modulation of glazing properties to improve energy efficiency and users’ comfort was tested comparing the EC windows with a typical law-compliant static commercial glazing system and with a clear windows. To better understand the performances of the proposed EC film, six different locations – ranging from Seville to Helsinki – were selected throughout the European continent to conduct energy and daylighting analyses on three different exposures (east, south, west). The results obtained show reductions of summer cooling and winter heating as well in all the locations considered. Eventually, the effect of electrochromic switching of transmittance on the indoor visual comfort, is considered using a well-established metric: Useful Daylight Illuminance; with regards to daylight analyses, a significant reduction of hours in which excessive illuminance occurs was observed in all the locations considered, confirming that properly controlled EC devices improve both energy efficiency and visual comfort.
2023
Low-cost gel-polymer electrolytes for smart windows: effects on yearly energy consumption and visual comfort / Cannavale, Alessandro; Carlucci, Francesco; Pugliese, Marco; Maiorano, Vincenzo; Ayr, Ubaldo; Fiorito, Francesco. - In: ENERGY AND BUILDINGS. - ISSN 0378-7788. - STAMPA. - 301:(2023). [10.1016/j.enbuild.2023.113705]
File in questo prodotto:
File Dimensione Formato  
2023_Low-cost_gel-polymer_electrolytes_for_smart_windows_pdfeditoriale.pdf

accesso aperto

Descrizione: versione editoriale
Tipologia: Versione editoriale
Licenza: Creative commons
Dimensione 1.16 MB
Formato Adobe PDF
1.16 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/261141
Citazioni
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2