Label-free sensing is a promising approach for point-of-care testing devices. Among optical transducers, photonic crystal slabs (PCSs) have positioned themselves as an inexpensive yet versatile platform for label-free biosensing. A spectral resonance shift is observed upon biomolecular binding to the functionalized surface. Commonly, a PCS is read out by a spectrometer. Alternatively, the spectral shift may be translated into an intensity change by tailoring the system response. Intensity-based camera setups (IBCS) are of interest as they mitigate the need for postprocessing, enable spatial sampling, and have moderate hardware requirements. However, they exhibit modest performance compared with spectrometric approaches. Here, we show an increase of the sensitivity and limit of detection (LOD) of an IBCS by employing a sharp-edged cut-off filter to optimize the system response. We report an increase of the LOD from (7.1 ± 1.3) × 10−4 RIU to (3.2 ± 0.7) × 10−5 RIU. We discuss the influence of the region of interest (ROI) size on the achievable LOD. We fabricated a biochip by combining a microfluidic and a PCS and demonstrated autonomous transport. We analyzed the performance via refractive index steps and the biosensing ability via diluted glutathione S-transferase (GST) antibodies (1:250). In addition, we illustrate the speed of detection and demonstrate the advantage of the additional spatial information by detecting streptavidin (2.9 µg/mL). Finally, we present the detection of immunoglobulin G (IgG) from whole blood as a possible basis for point-of-care devices.

Intensity-Based Camera Setup for Refractometric and Biomolecular Sensing with a Photonic Crystal Microfluidic Chip / Kraft, F. A.; Lehmann, S.; Di Maria, C.; Joksch, L.; Fitschen-Ostern, S.; Fuchs, S.; Dell'Olio, F.; Gerken, M.. - In: BIOSENSORS. - ISSN 2079-6374. - 13:7(2023). [10.3390/bios13070687]

Intensity-Based Camera Setup for Refractometric and Biomolecular Sensing with a Photonic Crystal Microfluidic Chip

Di Maria C.;Dell'Olio F.;
2023-01-01

Abstract

Label-free sensing is a promising approach for point-of-care testing devices. Among optical transducers, photonic crystal slabs (PCSs) have positioned themselves as an inexpensive yet versatile platform for label-free biosensing. A spectral resonance shift is observed upon biomolecular binding to the functionalized surface. Commonly, a PCS is read out by a spectrometer. Alternatively, the spectral shift may be translated into an intensity change by tailoring the system response. Intensity-based camera setups (IBCS) are of interest as they mitigate the need for postprocessing, enable spatial sampling, and have moderate hardware requirements. However, they exhibit modest performance compared with spectrometric approaches. Here, we show an increase of the sensitivity and limit of detection (LOD) of an IBCS by employing a sharp-edged cut-off filter to optimize the system response. We report an increase of the LOD from (7.1 ± 1.3) × 10−4 RIU to (3.2 ± 0.7) × 10−5 RIU. We discuss the influence of the region of interest (ROI) size on the achievable LOD. We fabricated a biochip by combining a microfluidic and a PCS and demonstrated autonomous transport. We analyzed the performance via refractive index steps and the biosensing ability via diluted glutathione S-transferase (GST) antibodies (1:250). In addition, we illustrate the speed of detection and demonstrate the advantage of the additional spatial information by detecting streptavidin (2.9 µg/mL). Finally, we present the detection of immunoglobulin G (IgG) from whole blood as a possible basis for point-of-care devices.
2023
Intensity-Based Camera Setup for Refractometric and Biomolecular Sensing with a Photonic Crystal Microfluidic Chip / Kraft, F. A.; Lehmann, S.; Di Maria, C.; Joksch, L.; Fitschen-Ostern, S.; Fuchs, S.; Dell'Olio, F.; Gerken, M.. - In: BIOSENSORS. - ISSN 2079-6374. - 13:7(2023). [10.3390/bios13070687]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/262167
Citazioni
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact