Hydrogen production and storage in hybrid systems is a promising solution for sustainable energy transition, decoupling energy generation from demand and boosting the deployment of renewable energy. Nonetheless, the optimal and cost-effective design of hybrid hydrogen-based systems is crucial to tackle existing limitations in the diffusion of these systems. The present study explores net-zero energy management via a multi-objective optimization algorithm for an outdoor test facility equipped with a hydrogen-based hybrid energy production system. Aimed at enabling efficient integration of hydrogen fuel cell system, the proposed solution attempts to maximize the renewable factor (RF) and carbon mitigation in the hybrid system as well as to minimize the grid dependency and the life cycle cost (LCC) of the system. In this context, the techno-enviro-economic optimization of the hybrid system is conducted by employing a statistical approach to identify optimal design variables and conflictive objective functions. To examine interactions in components of the hybrid system, a series of dynamic simulations are carried out by developing a TRNSYS code coupled with the OpenStudio/EnergyPlus plugin. The obtained results indicate a striking disparity in the monthly RF values as well as the hydrogen production rate, and, therefore, in the level of grid dependency. It is shown that the difference in LCC between optimization scenarios suggested by the design of experiments could reach $15,780, corresponding to 57 % of the mean initial cost. The LCOE value yielded for optimum scenarios varies between 0.389 and 0.537 $/kWh. The scenario with net-zero target demonstrates the lowest LCOE value and the highest carbon mitigation, i.e., 828 kg CO2/yr, with respect to the grid supply case. However, the LCC in this scenario exceeds $57,370, which is the highest among all optimum scenarios. Furthermore, it was revealed that the lowest RF in optimal scenarios is equal to 66.2 % and belongs to the most economical solution.

Net-zero energy management through multi-criteria optimizations of a hybrid solar-hydrogen energy system for a laboratory in Toronto, Canada / Abdolmaleki, Leila; Jahanbin, Aminhossein; Berardi, Umberto. - In: ENERGY AND BUILDINGS. - ISSN 0378-7788. - ELETTRONICO. - 312:(2024). [10.1016/j.enbuild.2024.114186]

Net-zero energy management through multi-criteria optimizations of a hybrid solar-hydrogen energy system for a laboratory in Toronto, Canada

Jahanbin, Aminhossein
;
Berardi, Umberto
2024-01-01

Abstract

Hydrogen production and storage in hybrid systems is a promising solution for sustainable energy transition, decoupling energy generation from demand and boosting the deployment of renewable energy. Nonetheless, the optimal and cost-effective design of hybrid hydrogen-based systems is crucial to tackle existing limitations in the diffusion of these systems. The present study explores net-zero energy management via a multi-objective optimization algorithm for an outdoor test facility equipped with a hydrogen-based hybrid energy production system. Aimed at enabling efficient integration of hydrogen fuel cell system, the proposed solution attempts to maximize the renewable factor (RF) and carbon mitigation in the hybrid system as well as to minimize the grid dependency and the life cycle cost (LCC) of the system. In this context, the techno-enviro-economic optimization of the hybrid system is conducted by employing a statistical approach to identify optimal design variables and conflictive objective functions. To examine interactions in components of the hybrid system, a series of dynamic simulations are carried out by developing a TRNSYS code coupled with the OpenStudio/EnergyPlus plugin. The obtained results indicate a striking disparity in the monthly RF values as well as the hydrogen production rate, and, therefore, in the level of grid dependency. It is shown that the difference in LCC between optimization scenarios suggested by the design of experiments could reach $15,780, corresponding to 57 % of the mean initial cost. The LCOE value yielded for optimum scenarios varies between 0.389 and 0.537 $/kWh. The scenario with net-zero target demonstrates the lowest LCOE value and the highest carbon mitigation, i.e., 828 kg CO2/yr, with respect to the grid supply case. However, the LCC in this scenario exceeds $57,370, which is the highest among all optimum scenarios. Furthermore, it was revealed that the lowest RF in optimal scenarios is equal to 66.2 % and belongs to the most economical solution.
2024
Net-zero energy management through multi-criteria optimizations of a hybrid solar-hydrogen energy system for a laboratory in Toronto, Canada / Abdolmaleki, Leila; Jahanbin, Aminhossein; Berardi, Umberto. - In: ENERGY AND BUILDINGS. - ISSN 0378-7788. - ELETTRONICO. - 312:(2024). [10.1016/j.enbuild.2024.114186]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/278680
Citazioni
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 6
social impact