An approach to dynamic focusing of ultrasound linear array scanners is presented, leading to the unique capability of implementing a focus that continuously tracks the return signal along the penetration depth. An electronically variable lens is obtained by a heterodyning process, in which the phases of echo signals at the array elements are equalized by mixing with suitable reference oscillations. These are generated by control of a single voltage-controlled oscillator, whose frequency is properly varied in synchronism with the delay of signal from different depths. The technique has been experimentally demonstrated by modifying the focusing processor of a conventional echographic linear scanner. Superior performances have been obtained with respect to fixed-focus operation mode. The image quality results are comparable with those of multizone-focus operation mode, in which the focus is varied over more transmit/receive cycles at the expense of lower frame rate.
Synchronous dynamic focusing for ultrasound imaging / Manes, G.; Tortoli, P.; Andreuccetti, F.; Avitabile, G.; Atzeni, C.. - In: IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL. - ISSN 0885-3010. - STAMPA. - 35:1(1988), pp. 14-21. [10.1109/58.4143]
Synchronous dynamic focusing for ultrasound imaging
G. Avitabile;
1988-01-01
Abstract
An approach to dynamic focusing of ultrasound linear array scanners is presented, leading to the unique capability of implementing a focus that continuously tracks the return signal along the penetration depth. An electronically variable lens is obtained by a heterodyning process, in which the phases of echo signals at the array elements are equalized by mixing with suitable reference oscillations. These are generated by control of a single voltage-controlled oscillator, whose frequency is properly varied in synchronism with the delay of signal from different depths. The technique has been experimentally demonstrated by modifying the focusing processor of a conventional echographic linear scanner. Superior performances have been obtained with respect to fixed-focus operation mode. The image quality results are comparable with those of multizone-focus operation mode, in which the focus is varied over more transmit/receive cycles at the expense of lower frame rate.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.