Residential energy districts are increasingly transitioning from passive consumers to prosumer-oriented hubs, where achieving high self-supply and low emissions requires coordinated design of PV generation, hybrid energy storage systems (HESS), and sector-coupling technologies. However, optimal design of district-scale multi-vector hubs remains challenging since techno-economic and environmental outcomes are driven by nonlinear constraints and time-coupled dynamics. This study develops a surrogate-assisted Bayesian multi-criteria decision-making (MCDM) workflow for optimal design of residential district-scale PV–HESS hubs. Formulated as a six-dimensional (6-D) continuous design problem, a space-filling design of experiments is used to generate a compact but representative database of dynamic simulations, from which probabilistic regressors are trained to emulate the high-fidelity responses across four criteria capturing energy positivity, environmental impact, grid exchange dynamics, and life-cycle cost. The Bayesian framework enables efficient Pareto inference, uncertainty-informed screening of candidate solutions, and knee-point identification, followed by re-simulation verification at the decision points. The trained Gaussian Process surrogates, verified via K-fold cross-validation, achieve high predictive fidelity with R2 ≥ 0.9891, NRMSE ≤ 0.028, and MAPE typically within 1–4 %, while knee-point re-simulation deviations remain below 6.64 %. Post-sizing assessment of the selected knee design shows 6,467 h of grid-independent operation (≈9 months of autonomy), with the combined battery-hydrogen contribution maximized in the shoulder seasons, peaking in autumn (36.8 %). Benchmarking against PV-only demonstrates a marked improvement in environmental performance, with the emission mitigation factor increasing from 42.1 % to 63.6 % and reduced export ratio. Sensitivity analysis reveals that the export-to-grid ratio is the most sensitive target to sizing perturbations, whereas the emission factor is comparatively the least sensitive.

Bayesian multi-criteria decision-making for optimal capacity planning of district-scale multi-vector energy hubs / Selicati, V., Jahanbin, A., Berardi, U.. - In: SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS. - ISSN 2213-1388. - 91:(2026), pp. 105082.105082-105082.105082. [10.1016/j.seta.2026.105082]

Bayesian multi-criteria decision-making for optimal capacity planning of district-scale multi-vector energy hubs

Selicati V.;Jahanbin A.;Berardi U.
2026

Abstract

Residential energy districts are increasingly transitioning from passive consumers to prosumer-oriented hubs, where achieving high self-supply and low emissions requires coordinated design of PV generation, hybrid energy storage systems (HESS), and sector-coupling technologies. However, optimal design of district-scale multi-vector hubs remains challenging since techno-economic and environmental outcomes are driven by nonlinear constraints and time-coupled dynamics. This study develops a surrogate-assisted Bayesian multi-criteria decision-making (MCDM) workflow for optimal design of residential district-scale PV–HESS hubs. Formulated as a six-dimensional (6-D) continuous design problem, a space-filling design of experiments is used to generate a compact but representative database of dynamic simulations, from which probabilistic regressors are trained to emulate the high-fidelity responses across four criteria capturing energy positivity, environmental impact, grid exchange dynamics, and life-cycle cost. The Bayesian framework enables efficient Pareto inference, uncertainty-informed screening of candidate solutions, and knee-point identification, followed by re-simulation verification at the decision points. The trained Gaussian Process surrogates, verified via K-fold cross-validation, achieve high predictive fidelity with R2 ≥ 0.9891, NRMSE ≤ 0.028, and MAPE typically within 1–4 %, while knee-point re-simulation deviations remain below 6.64 %. Post-sizing assessment of the selected knee design shows 6,467 h of grid-independent operation (≈9 months of autonomy), with the combined battery-hydrogen contribution maximized in the shoulder seasons, peaking in autumn (36.8 %). Benchmarking against PV-only demonstrates a marked improvement in environmental performance, with the emission mitigation factor increasing from 42.1 % to 63.6 % and reduced export ratio. Sensitivity analysis reveals that the export-to-grid ratio is the most sensitive target to sizing perturbations, whereas the emission factor is comparatively the least sensitive.
2026
Bayesian multi-criteria decision-making for optimal capacity planning of district-scale multi-vector energy hubs / Selicati, V., Jahanbin, A., Berardi, U.. - In: SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS. - ISSN 2213-1388. - 91:(2026), pp. 105082.105082-105082.105082. [10.1016/j.seta.2026.105082]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/310182
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
  • OpenAlex ND
social impact