A PET imaging system demonstrator based on LYSO crystal arrays coupled to SiPM matrices is under construction at the University and INFN of Pisa. Two SiPM matrices, composed of 8×8 SiPM pixels, and 1,5 mm pitch, have been coupled one to one to a LYSO crystals array and read out by a custom electronics system. front-end ASICs were used to read 8 channels of each matrix. Data from each front-end were multiplexed and sent to a DAQ board for the digital conversion; a motherboard collects the data and communicates with a host computer through a USB port for the storage and off-line data processing. In this paper we show the first preliminary tomographic image of a point-like radioactive source acquired with part of the two detection heads in time coincidence.

Proof of concept of an imaging system demonstrator for PET applications with SiPM / M., Morrocchi; S., Marcatili; N., Belcari; M. G., Bisogni; G., Collazuol; G., Ambrosi; C., Santoni; Corsi, Francesco; M., Foresta; Marzocca, Cristoforo; Matarrese, Gianvito; G., Sportelli; P., Guerra; A., Santos; A., Del Guerra. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 720:(2013), pp. 67-69. [10.1016/j.nima.2012.12.033]

Proof of concept of an imaging system demonstrator for PET applications with SiPM

CORSI, Francesco;MARZOCCA, Cristoforo;MATARRESE, Gianvito;
2013-01-01

Abstract

A PET imaging system demonstrator based on LYSO crystal arrays coupled to SiPM matrices is under construction at the University and INFN of Pisa. Two SiPM matrices, composed of 8×8 SiPM pixels, and 1,5 mm pitch, have been coupled one to one to a LYSO crystals array and read out by a custom electronics system. front-end ASICs were used to read 8 channels of each matrix. Data from each front-end were multiplexed and sent to a DAQ board for the digital conversion; a motherboard collects the data and communicates with a host computer through a USB port for the storage and off-line data processing. In this paper we show the first preliminary tomographic image of a point-like radioactive source acquired with part of the two detection heads in time coincidence.
2013
Proof of concept of an imaging system demonstrator for PET applications with SiPM / M., Morrocchi; S., Marcatili; N., Belcari; M. G., Bisogni; G., Collazuol; G., Ambrosi; C., Santoni; Corsi, Francesco; M., Foresta; Marzocca, Cristoforo; Matarrese, Gianvito; G., Sportelli; P., Guerra; A., Santos; A., Del Guerra. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 720:(2013), pp. 67-69. [10.1016/j.nima.2012.12.033]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/3925
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact