In a 3-year joint research project, approved in 1995 by the European Commission, methods for advanced treatment and disinfection of municipal wastewater to permit reuse in agriculture were investigated. Pathogen inactivation, disinfection by-products (DBP) formation and the cost effectiveness of disinfection methods involving UV rays, ozone (O-3) and peracetic acid (PAA were evaluated. The investigation was carried out on municipal effluents which had received different degrees of treatment (secondary, clarified, clarified-filtered) in a 100 m(3)/h pilot plant that was designed, built and operated at West Bari (S. Italy) municipal wastewater treatment plant. Under the experimental conditions investigated, the WHO microbial guideline for unrestricted reuse of wastewater in agriculture (1,000 CFU/100ml for Faecal Coliforms) was easily achieved with all three disinfectants, while the corresponding Italian standard (2 CFU/100ml) was effectively met only with UV at an O&M cost in the range 17.5-35 EURO/1000m(3). Log-inactivation values greater than or equal to 5 for both UV and PAA and greater than or equal to 3 for O-3 were obtained; selected pathogens were affected by UV and, in part, by O-3. No DBPs were detected with UV and PAA, while limited formation of aldehydes was found with O-3.

Advanced treatment and disinfection for municipal wastewater reuse in agriculture / Liberti, L.; Notarnicola, M.. - In: WATER SCIENCE AND TECHNOLOGY. - ISSN 0273-1223. - STAMPA. - 40:4-5(1999), pp. 235-245. [10.1016/S0273-1223(99)00505-3]

Advanced treatment and disinfection for municipal wastewater reuse in agriculture

Liberti, L.;Notarnicola, M.
1999-01-01

Abstract

In a 3-year joint research project, approved in 1995 by the European Commission, methods for advanced treatment and disinfection of municipal wastewater to permit reuse in agriculture were investigated. Pathogen inactivation, disinfection by-products (DBP) formation and the cost effectiveness of disinfection methods involving UV rays, ozone (O-3) and peracetic acid (PAA were evaluated. The investigation was carried out on municipal effluents which had received different degrees of treatment (secondary, clarified, clarified-filtered) in a 100 m(3)/h pilot plant that was designed, built and operated at West Bari (S. Italy) municipal wastewater treatment plant. Under the experimental conditions investigated, the WHO microbial guideline for unrestricted reuse of wastewater in agriculture (1,000 CFU/100ml for Faecal Coliforms) was easily achieved with all three disinfectants, while the corresponding Italian standard (2 CFU/100ml) was effectively met only with UV at an O&M cost in the range 17.5-35 EURO/1000m(3). Log-inactivation values greater than or equal to 5 for both UV and PAA and greater than or equal to 3 for O-3 were obtained; selected pathogens were affected by UV and, in part, by O-3. No DBPs were detected with UV and PAA, while limited formation of aldehydes was found with O-3.
1999
Advanced treatment and disinfection for municipal wastewater reuse in agriculture / Liberti, L.; Notarnicola, M.. - In: WATER SCIENCE AND TECHNOLOGY. - ISSN 0273-1223. - STAMPA. - 40:4-5(1999), pp. 235-245. [10.1016/S0273-1223(99)00505-3]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/477
Citazioni
  • Scopus 127
  • ???jsp.display-item.citation.isi??? 110
social impact