Next generation PET scanners should fulfill very high requirements in terms of spatial, energy and timing resolution. Modern scanner performances are inherently limited by the use of standard photomultiplier tubes. The use of Silicon Photomultiplier (SiPM) matrices is proposed for the construction of a 4D PET module based on LSO continuous crystals, which is envisaged to replace the standard PET block detector. The expected spatial resolution of the module for the photon hit position is below 1 mm, and it will perform at the same time, the Depth Of Interaction (DOI) calculation and the Time Of Flight (TOF) measurement. The use of large area multi-pixel Silicon Photomultiplier (SiPM) detectors requires the development of a multichannel Digital Acquisition system (DAQ) as well as of a dedicated front-end in order not to degrade the intrinsic detector performances. We have developed a flexible and modular DAQ system for the read-out of two modules in time coincidence for Positron Emission Tomography (PET) applications. The DAQ system is based on a previously developed custom front-end ASIC chip (BASIC) which allows to read-out SiPM matrices preserving their spectroscopy and timing capabilities. Here we describe the acquisition system architecture and its characterization measurements.
Development and characterization of a modular acquisition system for a 4D PET block detector / Marcatili, S.; Belcari, N.; Bisogni, M. G.; Collazuol, G.; Ambrosi, G.; Corsi, Francesco; Foresta, M.; Marzocca, Cristoforo; Matarrese, Gianvito; Sportelli, G.; Guerra, P.; Santos, A.; Del Guerra, A.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - A659:1(2011), pp. 494-498. [10.1016/j.nima.2011.08.042]
Development and characterization of a modular acquisition system for a 4D PET block detector
CORSI, Francesco;MARZOCCA, Cristoforo;MATARRESE, Gianvito;
2011-01-01
Abstract
Next generation PET scanners should fulfill very high requirements in terms of spatial, energy and timing resolution. Modern scanner performances are inherently limited by the use of standard photomultiplier tubes. The use of Silicon Photomultiplier (SiPM) matrices is proposed for the construction of a 4D PET module based on LSO continuous crystals, which is envisaged to replace the standard PET block detector. The expected spatial resolution of the module for the photon hit position is below 1 mm, and it will perform at the same time, the Depth Of Interaction (DOI) calculation and the Time Of Flight (TOF) measurement. The use of large area multi-pixel Silicon Photomultiplier (SiPM) detectors requires the development of a multichannel Digital Acquisition system (DAQ) as well as of a dedicated front-end in order not to degrade the intrinsic detector performances. We have developed a flexible and modular DAQ system for the read-out of two modules in time coincidence for Positron Emission Tomography (PET) applications. The DAQ system is based on a previously developed custom front-end ASIC chip (BASIC) which allows to read-out SiPM matrices preserving their spectroscopy and timing capabilities. Here we describe the acquisition system architecture and its characterization measurements.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.